Low Temperature Overvoltage Bypass™
Part Number LTOB 0, 5 or 10oC.
Automatically bypasses PV module at low temperatures to drop Voc.
Complete safety at the lowest of temperatures without compromising the high temperature performance.
Click here for detailed specs in PDF version
Protect equipment from high PV Open Circuit Voltage at Low Temperatures
Size the PV array for maximum energy harvest Every PV array can now be sized without being limited by the high open-circuit voltages present at low temperatures. The Apollo Solar LTOB automatically switches modules out of the circuit if the temperature falls below the specified point.
Simple, Reliable Operation The LTOB removes 1 module from the 6 module string keeping Voc under 140v. When the temperature falls below 10OC (50OF) the LTOB turns on and the top module is switched out of the circuit so the Voc drops to 120 volts. The 5 module string is below the 140volt limit down to -40O. When the temperature rises, the LTOB turns off and the module is switched back into the circuit.
Fast, Easy Installation The Apollo Solar LTOB units are supplied with an adhesive tape on the back side. Just peel off the backing layer and stick the LTOB and Temperature Sensor to the back of the PV module to be cut from the string. Simply snap the MC connectors together. At normal or high temperatures the LTOB connects straight through and the PV array functions normally.
When or why do I need the Low Temperature Overvoltage Bypass?